Free Sales Ending Soon - 100% Valid H12-425_V2.0 Exam Dumps with 415 Questions Verified H12-425_V2.0 dumps Q As on your HCIP-DCF-BFDO Exam Questions Certain Success! NEW QUESTION 12 What are the alarm management functions supported by the ECC800? (Multiple choice) A. Alarm parameter setting B. View historical alarms C. Alarm data export D. Filter alerts Answer: A,B,C,D NEW QUESTION 13 When UPS5000-E [...]

Free Sales Ending Soon - 100% Valid H12-425_V2.0 Exam Dumps with 415 Questions [Q12-Q36]

Share

Free Sales Ending Soon - 100% Valid H12-425_V2.0 Exam Dumps with 415 Questions

Verified H12-425_V2.0 dumps Q&As on your HCIP-DCF-BFDO Exam Questions Certain Success!

NEW QUESTION 12
What are the alarm management functions supported by the ECC800? (Multiple choice)

  • A. Alarm parameter setting
  • B. View historical alarms
  • C. Alarm data export
  • D. Filter alerts

Answer: A,B,C,D

 

NEW QUESTION 13
When UPS5000-E shares a battery pack, the battery capacity parameter of each UPS is set to the total capacity of the entire battery pack.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 14
When UPS2000-G shuts down the single machine of the shutdown system, it needs to ().

  • A. Only one shutdown operation is required for the machine
  • B. Shut down all UPSs in the system
  • C. Perform 2 consecutive shutdown operations on the machine
  • D. Directly disconnect the input of the machine

Answer: C

 

NEW QUESTION 15
Huawei's main temperature control solution for small and medium-sized computer rooms is?

  • A. Room-level air cooling solution
  • B. Row-level chilled water with micro-modules
  • C. Room-level chilled water solution
  • D. Row-level air cooling with micro-modules

Answer: D

 

NEW QUESTION 16
The refrigerant cylinder of Huawei air-cooled air conditioner does not need to be placed upside down on the electronic scale when charging refrigerant.

  • A. True
  • B. False

Answer: B

 

NEW QUESTION 17
Which of the following UPS models supports bypass hot swap? (Multiple choice)

  • A. UPS5000-E
  • B. APM series
  • C. UPS5000-A
  • D. PX250 series

Answer: A,B,D

 

NEW QUESTION 18
In the UPS5000 configuration, different battery schemes can be obtained by adjusting the number of battery strings and the number of battery cells in a single group.

  • A. False
  • B. True

Answer: B

 

NEW QUESTION 19
The user can modify the IP address of the ECC800 from the () menu on the ECC800WEB interface.

  • A. Micro module settings
  • B. Time setting
  • C. Video IP settings
  • D. Monitoring module IP

Answer: D

 

NEW QUESTION 20
When installing the power line of UPS5000-E, if the main and side sources are different, you need to remove the bronze plate connecting the bypass and the main circuit first, and then connect the main circuit and the bypass input respectively.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 21
FusionModule800 can only support down pipe.

  • A. True
  • B. False

Answer: B

 

NEW QUESTION 22
The EPO status interface of UPS5000-E can choose open or normally closed interface according to actual use.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 23
There is no limit to the total length of the refrigerant piping of the direct expansion air-cooled air conditioner.

  • A. True
  • B. False

Answer: B

 

NEW QUESTION 24
The UPS5000-E power chess block adopts a fan fault-tolerant design. When one of the fans is damaged, what percentage of the power module can still be loaded?

  • A. 0.3
  • B. 0.5
  • C. 0.6
  • D. 0.25

Answer: B

 

NEW QUESTION 25
In the FusionModule2000 refrigeration system, which of the following is the optional temperature control type? (Multiple choice)

  • A. Row level chilled water 65kW
  • B. Full cabinet 42kW air cooling
  • C. Half cabinet 25kW air cooling
  • D. Half cabinet 30kW water cooling

Answer: B,C

 

NEW QUESTION 26
A system is configured with 15min battery backup time, and the discharge termination voltage of the battery cell should select?

  • A. 1.60V
  • B. 1.75V
  • C. 1.67V
  • D. 1.80V

Answer: B

 

NEW QUESTION 27
FusionModule500&FusionModule800 remote WEB interface monitoring must be configured with unified network management software.

  • A. False
  • B. True

Answer: B

 

NEW QUESTION 28
By setting the mailbox parameters, the NETECO system will send emails to notify users according to the set rules.

  • A. False
  • B. True

Answer: B

 

NEW QUESTION 29
The similar models of Eaton and UPS5000-A 30kVA120kVA are ().

  • A. NXR
  • B. 0
  • C. 1

Answer: C

 

NEW QUESTION 30
What is the channel type of a typical configuration of FusionModule800? Is a cold aisle or a hot aisle?

  • A. Cold Aisle
  • B. Hot Aisle

Answer: A

 

NEW QUESTION 31
How many KG is the static load of the FusionModule2000 cabinet?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

 

NEW QUESTION 32
The default management authority user name of the ECC800 is admin, and admin has all the authority to operate the WEB interface functions.

  • A. False
  • B. True

Answer: B

 

NEW QUESTION 33
Which manufacturers have 50KVA power modules? (Multiple choice)

  • A. Schneider
  • B. Huawei
  • C. INVT
  • D. Emerson

Answer: B,C

 

NEW QUESTION 34
In the water-testing natural cooling scheme, the cooling tower can directly provide cooling water to the air conditioner to complete the cooling.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 35
A UPS system is configured with a single 50mm "2 (209A) cable, and the maximum current capacity allowed by the system is?

  • A. 174A
  • B. 104A
  • C. 209A
  • D. 160A

Answer: C

 

NEW QUESTION 36
......