[Jun 10, 2025] Today Updated SDLCSA Exam Dumps Actual Questions SDLCSA exam dumps with real Supermicro questions and answers NEW QUESTION # 13 What are the full steps and proper order for replacing a failed power supply unit in the SYS-421GE-TNHR2- LCC system? A. Lift the blue lock to unlock the release lever Push the release lever down and in until it clicks Ensure the red lock on the release lever [...]

[Jun 10, 2025] Today Updated SDLCSA Exam Dumps Actual Questions [Q13-Q31]

Share

[Jun 10, 2025] Today Updated SDLCSA Exam Dumps Actual Questions

SDLCSA exam dumps with real Supermicro questions and answers

NEW QUESTION # 13
What are the full steps and proper order for replacing a failed power supply unit in the SYS-421GE-TNHR2- LCC system?

  • A. Lift the blue lock to unlock the release lever > Push the release lever down and in until it clicks > Ensure the red lock on the release lever is locked
  • B. Lift the release lever and use it to pull out the failed power supply unit > Replace the failed power supply unit with a new one > Push the new power supply unit into the tray > Push the release lever down and in until it clicks
  • C. Lift the red lock to unlock the release lever > Lift the release lever and use it to pull out the failed power supply unit > Replace the failed power supply unit with a new one > Ensure the gold connector pins are on the top > Push the new power supply unit into the tray > Push the release lever down and in until it clicks > Ensure the red lock on the release lever is locked
  • D. Lift the yellow lock to unlock the release lever > Lift the release lever and use it to pull out the failed power supply unit > Replace the failed power supply unit with a new one

Answer: C

Explanation:
Replacing a PSU in Supermicro's SYS-421GE-TNHR2-LCC follows a detailed, safety-focused process:
Lift the red lock to unlock the release lever: Red is a common Supermicro color for PSU locks.
Lift the release lever and use it to pull out the failed PSU: Standard hot-swap mechanism.
Replace the failed PSU with a new one: Swap the unit.
Ensure the gold connector pins are on the top: Correct orientation for connection.
Push the new PSU into the tray: Slide it in fully.
Push the release lever down and in until it clicks: Locks the PSU.
Ensure the red lock is locked: Confirms security.
Option B covers all steps comprehensively, aligning with Supermicro's DLC system PSU replacement (e.g., SYS-420 manuals). A is incomplete, C reverses steps, and D skips locking, making B correct.
References: Supermicro PSU replacement guides, DLC system power protocols.


NEW QUESTION # 14
The power supply units (PSUs) in the SYS-421GE-TNHR2-LCC system are at the back of the chassis, and next to a dummy PSU tray. True or False.

  • A. True
  • B. False

Answer: A

Explanation:
In Supermicro's high-end servers like the SYS-421GE-TNHR2-LCC, PSUs are typically located at the back of the chassis for accessibility and cooling efficiency, a design consistent with DLC rack-scale solutions (e.g., SYS-420GP-TNAR). The mention of a "dummy PSU tray" suggests a placeholder or empty slot, common in modular designs to maintain airflow or allow future expansion. This layout is standard in Supermicro's DLC systems, where PSUs power both compute and cooling components (e.g., pumps, CDUs). No contradicting evidence exists, and True (A) aligns with Supermicro's chassis architecture, making it the correct answer.
References: Supermicro chassis design specs, DLC system PSU placement.


NEW QUESTION # 15
There are 2 slots for the M.2 drive. If only one is installed, it is important to note which slot it is removed from so that it can be re-installed to the same location. True or False.

  • A. True
  • B. False

Answer: B

Explanation:
In Supermicro systems with 2 M.2 slots (e.g., SYS-421GE-TNHR2-LCC), the slots are typically interchangeable unless specified by BIOS or hardware configuration (rare in standard setups). Re-installing an
M.2 drive to the same slot isn't critical for functionality, as the system auto-detects it, per Supermicro manuals. False (B) aligns with DLC system flexibility, making it correct over A.References:Supermicro M.2 installation guides, DLC system storage configs.


NEW QUESTION # 16
How many screws need to be removed from the metal bracket that holds down the LPIO board / BMC cable?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

Explanation:
The LPIO (Low-Profile IO) board and BMC cable in Supermicro systems are typically secured by a minimal number of screws for quick serviceability, a principle in DLC designs like the SYS-421GE-TNHR2-LCC.
Based on similar systems (e.g., SYS-420GP-TNAR), the metal bracket holding these components is fastened with 2 screws, balancing security and ease of access. Higher counts like 8 (A), 5 (B), or 6 (D) are excessive for a small bracket, while 2 (C) matches Supermicro's standard for IO-related brackets. In DLC contexts, modularity is key, supporting C as the verified number.
References: Supermicro IO board installation guides, DLC system service efficiency.


NEW QUESTION # 17
What are the full steps and proper order for replacing a failed NVMe SSD drive in the SYS-421GE-TNHR2- LCC system?

  • A. Remove failed drive/drive carrier from chassis carriage > Remove failed drive from drive carrier > Insert new drive into drive carrier > Insert new drive/drive carrier into chassis carriage
  • B. Remove failed drive/drive carrier from chassis carriage > Insert new drive/drive carrier into chassis carriage > Remove failed DIMM from drive carrier > Insert new drive into drive carrier
  • C. Remove failed drive/drive carrier from chassis carriage > Remove failed drive from drive carrier > Insert new drive/drive carrier into chassis carriage > Insert new fan into drive carrier
  • D. Remove failed drive from drive carrier > Remove CPU from chassis carriage > Insert new drive into drive carrier > Insert new drive/drive carrier into chassis carriage

Answer: A

Explanation:
Replacing an NVMe SSD in a Supermicro system like the SYS-421GE-TNHR2-LCC, which supports Direct Liquid Cooling, follows a standard procedure for hot-swappable drives in high-performance servers. The correct sequence, as outlined in Supermicro's general server maintenance guides (e.g., for SYS-420 series or similar DLC-enabled systems), is:
* Remove failed drive/drive carrier from chassis carriage: NVMe drives are housed in carriers for easy access and hot-swap capability, a feature emphasized in Supermicro's DLC rack-scale solutions for minimizing downtime in AI/HPC workloads.
* Remove failed drive from drive carrier: The carrier is opened to extract the faulty NVMe SSD.
* Insert new drive into drive carrier: The replacement NVMe SSD is secured into the carrier.
* Insert new drive/drive carrier into chassis carriage: The carrier is reinserted into the chassis, ensuring proper connection.Option D accurately reflects this logical order. Option A incorrectly involves DIMMs (memory modules), B mentions a fan (unrelated to NVMe replacement), and C involves a CPU (not part of the process). Supermicro's DLC systems prioritize modularity and serviceability, making D the verified procedure.References:Supermicro NVMe SSD replacement guides (e.g., SYS-420GP-TNAR Manual), DLC solution serviceability features.


NEW QUESTION # 18
Before the fan board can be removed from the motherboard tray, all 4 of the fans' power connectors must be disconnected. True or False.

  • A. True
  • B. False

Answer: A

Explanation:
In Supermicro systems like the SYS-421GE-TNHR2-LCC, the fan board connects multiple fans (often 4 in high-end setups) to the motherboard tray. Removing the fan board requires disconnecting all 4 fans' power connectors first to avoid damage or electrical hazards, a standard step in Supermicro's service guides (e.g., SYS-420GP-TNAR). Even in DLC systems, where liquid cooling dominates, fans supplement air cooling, and their power must be safely disconnected. True (A) reflects Supermicro's safety and maintenance protocols, making it correct over B.
References: Supermicro fan board removal guides, DLC hybrid cooling safety.


NEW QUESTION # 19
Which card would you most likely connect to the AOM module (AOM-GP401-PCIE)?

  • A. Debit card
  • B. AOC NIC card
  • C. Credit card
  • D. AOM card

Answer: B


NEW QUESTION # 20
When removing the PCIe tray, where are the screws located and how many screws need to be loosened?

  • A. There are 4 screws that need to be loosened, two on each side of the front of the PCIe tray
  • B. There are 6 screws that need to be loosened, three on each side on the front of the PCIe tray
  • C. There are 2 screws that need to be loosened, one on each side of the front of the PCIe tray
  • D. There are 2 screws that need to be loosened, one on each side on the sides of the GPU tray

Answer: A

Explanation:
Removing the PCIe tray in the SYS-421GE-TNHR2-LCC requires loosening4 screws, two on each side of the front, per Supermicro's standard tray removal (e.g., SYS-420GP-TNAR). This ensures secure detachment of the heavy, DLC-integrated tray. B (6 screws) is excessive, C misplaces screws to a GPU tray's sides, and D (2 screws) under-secures. Supermicro's DLC systems balance stability and serviceability, making A correct.
References:Supermicro PCIe tray removal guides, DLC system tray specs.


NEW QUESTION # 21
Which type of Liquid Cooling is discussed in this training?

  • A. Direct to Chip (DLC)
  • B. Rear Door Heat Exchanger (RDHx)
  • C. Immersion Cooling (ILC)
  • D. Evaporative Cooling

Answer: A

Explanation:
The training focuses on Supermicro'sDirect to Chip (DLC)liquid cooling, as indicated by the context of SYS-
421GE-TNHR2-LCC and Supermicro's expertise in DLC solutions (e.g., cold plates, CDUs up to 100kW).
DLC circulates coolant directly to CPUs/GPUs, reducing OPEX by 40% and supporting high-density racks. A (RDHx) cools via rear doors, B (Evaporative) uses evaporation, and C (ILC) submerges servers-none match Supermicro's DLC emphasis here. D is the verified type.References:Supermicro DLC whitepapers, SYS-
421GE-TNHR2-LCC cooling specs.


NEW QUESTION # 22
How many screws need to be removed from the internal fan to release it from the fan housing?

  • A. 0
  • B. 1
  • C. The fan has no screws that need to be removed
  • D. 2

Answer: D

Explanation:
Internal fans in Supermicro systems, including the SYS-421GE-TNHR2-LCC, are typically secured to their housing with 4 screws, a standard design for stability and ease of replacement (e.g., SYS-420 series manuals).
This allows secure mounting while facilitating serviceability, key in DLC systems where fans support hybrid cooling. 6 screws (A) is excessive, 2 (D) insufficient for stability, and C (no screws) contradicts standard fan assembly. Supermicro's DLC expertise ensures practical fan maintenance, making B the verified number.
References: Supermicro fan installation guides, DLC system cooling component specs.


NEW QUESTION # 23
Which 3 components of the SYS-421GE-TNHR2-LCC does this training discuss break/fix for? (Choose 3 answers)

  • A. Motherboard Tray
  • B. PCIe Tray
  • C. External Chassis
  • D. Bluetooth

Answer: A,B,C

Explanation:
The SYS-421GE-TNHR2-LCC, a DLC-enabled server, focuses break/fix training on key physical components per Supermicro's service scope:
* PCIe Tray: Houses GPUs/NICs, critical for DLC cooling (e.g., cold plates on GPUs).
* Motherboard Tray: Contains CPUs and core systems, also liquid-cooled in DLC setups.
* External Chassis: Encloses all components, requiring access for repairs.Bluetooth (C) is a connectivity feature, not a physical component for break/fix in this context, and Supermicro's DLC documentation (e.g., rack-scale solutions) emphasizes trays and chassis. Thus, A, B, and D are the focus.References:
Supermicro DLC solution breakdowns, SYS-420 series service guides.


NEW QUESTION # 24
To remove an AOC NIC card, simply pull the card straight up. True or False.

  • A. True
  • B. False

Answer: B

Explanation:
Removing an AOC NIC card in Supermicro systems like the SYS-421GE-TNHR2-LCC requires more than pulling straight up. Per standard procedures (e.g., SYS-420GP-TNAR), you must first unscrew the card from its bracket (1 screw) and release any retaining mechanisms (e.g., PCIe slot latch). Simply pulling risks damage to the card or slot, especially in DLC setups with dense configurations. False (B) reflects Supermicro' s emphasis on careful hardware handling, making it the correct answer.References:Supermicro AOC card removal guides, DLC system component safety.


NEW QUESTION # 25
What is the color of the PCIe tray's air shroud?

  • A. Clear
  • B. Black
  • C. White
  • D. Opaque

Answer: B

Explanation:
The air shroud in Supermicro systems, including those with Direct Liquid Cooling (DLC) solutions like the SYS-421GE-TNHR2-LCC, is typically designed to direct airflow (or in hybrid systems, assist with liquid cooling efficiency) and is made of plastic or composite materials. Based on Supermicro's standard design practices seen in technical documentation and product images (e.g., SYS-420GP-TNAR, a similar GPU server with DLC), the PCIe tray's air shroud is consistently black. This color aids in heat absorption and dissipation, aligning with Supermicro's focus on thermal efficiency in DLC systems, where cold plates and coolant distribution units (CDUs) manage heat directly at the chip level. White or clear shrouds are less common due to aesthetic and thermal considerations, and "opaque" is not a specific color designation. Thus, black is the correct choice, reflecting Supermicro's engineering standards for high-performance computing components.
References:Supermicro product images and manuals (e.g., SYS-420GP-TNAR User Manual), general DLC solution descriptions.


NEW QUESTION # 26
Before removing the LPIO board from the PCIe tray, what other component needs to be removed first?

  • A. Metal bracket
  • B. GPU tray
  • C. Air shroud
  • D. Motherboard tray

Answer: A

Explanation:
The LPIO (Low-Profile IO) board in Supermicro systems like the SYS-421GE-TNHR2-LCC, part of the PCIe tray, is typically secured by ametal bracketthat must be removed first. This bracket holds the LPIO board and associated cables (e.g., BMC cable) in place, as seen in similar designs (e.g., SYS-420GP-TNAR). Removing it involves unscrewing (often 2 screws) and lifting it off, granting access to the LPIO board. A (GPU tray) is a separate assembly, C (motherboard tray) is unrelated to the PCIe tray's LPIO, and D (air shroud) covers components but doesn't secure the board. Supermicro's DLC systems emphasize modular access, making B the correct step.References:Supermicro PCIe tray service guides, DLC system IO component layouts.


NEW QUESTION # 27
When reseating the PCIe tray, how do you know when the PCIe tray has been correctly inserted all the way back into the system?

  • A. The front of the PCIe tray should be slightly sticking out of the system
  • B. The levers on each side of the front of the PCIe tray that were in the down position should move up slightly
  • C. The levers on each side of the front of the PCIe tray that were in the up position should move down slightly
  • D. The levers on each side of the front of the PCIe tray that were in the down position should move up all the way into the locked position automatically

Answer: D

Explanation:
Reseating the PCIe tray in a Supermicro system like the SYS-421GE-TNHR2-LCC involvesaligning it with the chassis and locking it in place. Per Supermicro's design (e.g., SYS-420GP-TNAR), the tray has levers that start in the down (unlocked) position during insertion. When fully seated, these levers automatically move up to the locked position, clicking into place to secure the tray and ensure proper connection to power and cooling (e.g., DLC manifolds). Option A (sticking out) indicates incomplete insertion, B (slightly up) is insufficient, and C (up to down) reverses the mechanism. D reflects Supermicro's DLC system precision, ensuring tray stability.References:Supermicro PCIe tray installation guides, DLC component alignment standards.


NEW QUESTION # 28
Which card would you most likely connect to the AOM module (AOM-GP401-PCIE)?

  • A. Debit card
  • B. AOC NIC card
  • C. Credit card
  • D. AOM card

Answer: B

Explanation:
The AOM module (AOM-GP401-PCIE) in Supermicro systems is a PCIe-based add-on module, typically for expansion cards like NICs (Network Interface Cards). The AOC NIC card (Add-On Card, Network Interface Card) is the most likely connection, as Supermicro's AOM modules (e.g., in SYS-420 series) are designed to interface with AOC cards for networking in DLC systems. A (AOM card) is vague and not a standard term, while B and D (credit/debit cards) are irrelevant. Supermicro's DLC solutions integrate high-speed networking, making C the verified choice.
References: Supermicro AOM module specs, DLC system networking components.


NEW QUESTION # 29
......

Exam Sure Pass Supermicro Certification with SDLCSA exam questions: https://www.exam4free.com/SDLCSA-valid-dumps.html

SDLCSA Exam in First Attempt Guaranteed: https://drive.google.com/open?id=1kGq93wXEhDDDdT7w5r0yJoQwaZWhFWE7