[Jan 18, 2022] Pass Your 300-615 Dumps Free Latest Cisco Practice Tests
Get Top-Rated Cisco 300-615 Exam Dumps Now
Cisco 300-615: Troubleshooting Cisco Data Center Infrastructure Exam Certification Path
The Cisco 300-615: Troubleshooting Cisco Data Center Infrastructure exam certification path includes only one certification exam. There are two major types of resources for the study of certification exams first there are the study guides and therefore the books that are elaborated and appropriate for building knowledge from the ground up then there are video tutorial and lectures that may make study quite interesting nonetheless these demand time and concentration from the learner. Smart candidates who wish to create a solid foundation altogether examination topics and connected technologies typically mix video lectures with study guides to reap the advantages of each but 300-615 practice test or practice exam engines is one important study tool which goes typically unnoted by most candidates. 300-615 practice exams are designed with our experts to make exam prospects test their knowledge on skills attained in the course, as well as prospects become comfortable and familiar with the real exam environment. Statistics have indicated exam anxiety plays a much bigger role in students failure in the exam than the fear of the unknown. Exam4Free expert team recommends preparing some notes on these topics along with it don't forget to practice 300-615 exam dumps which been written by our expert team, each of these can assist you loads to clear this exam with excellent marks.
NEW QUESTION 18
Refer to the exhibit.
The initiator that has FC ID 0x970102 fails to communicate with the target that has FC ID 0x970200. What action resolves the issue?
- A. Reset the port for FC ID 0x970102 and FC ID 0x970200 to log in to the fabric.
- B. Reactivate the zoneset.
- C. Reset the port for FC ID 0x970209 and FC ID 0x9700c2 to log in to the fabric.
- D. Reconfigure the initiator and the target to be in the same zones.
Answer: D
NEW QUESTION 19
An engineer must replace a failed memory on a Cisco UCS B-Series Blade Server. After the replacement was done, the server has a "resolve slot" warning. Which server maintenance action resolves the issue?
- A. Reset the server.
- B. Perform diagnostic interrupt on the server.
- C. Decomission the server.
- D. Re-acknowlegement the server.
Answer: D
Explanation:
Section: Compute Platforms
NEW QUESTION 20
Refer to the exhibit.
The initiator that has FC ID 0x970102 fails to communicate with the target that has FC ID 0x970200. What action resolves the issue?
- A. Reset the port for FC ID 0x970102 and FC ID 0x970200 to log in to the fabric.
- B. Reactivate the zoneset.
- C. Reset the port for FC ID 0x970209 and FC ID 0x9700c2 to log in to the fabric.
- D. Reconfigure the initiator and the target to be in the same zones.
Answer: D
NEW QUESTION 21
Refer to the exhibit.
A new Cisco Nexus 5548 Switch connects to a network. SAN switching is configured on the switch. The switch fc2/10 NP uplink is shown in the exhibit. Which action ensures that fc2/10 is in an up state?
- A. Replace the SFP port module in fc2/10.
- B. Configure the admin port type E on the upstream switch that connects the port.
- C. Enable NPIV on the upstream switch that connects the port.
- D. Configure the BB_credit buffers on the upstream switch that connects the port.
Answer: C
NEW QUESTION 22
Drag and drop the commands from the left onto the correct categories on the right.
Answer:
Explanation:

NEW QUESTION 23
Drag and drop the commands from the left onto the correct categories on the right.
Answer:
Explanation:

NEW QUESTION 24
Refer to the exhibit.
The HSRP configuration in the exhibit fails to function. Which action resolves this issue?
- A. Enable IP redirects.
- B. Set the MTU to 1500 bytes.
- C. Configure the same HSRP group on both devices.
- D. Configure HSRP version 2.
Answer: A
NEW QUESTION 25
Refer to the Exhibit.
An Engineer cannot log in to the Cisco IMC page of the Cisco UCS C220 server. Which action resolve the issue?
- A. Use the DNS of the Cisco IMC webpage login page instead of the IP address for the connection to be secure.
- B. Replace the self-signed certificate that is installed on the Cisco IMC with a user certificate that is signed from the client corporate certificate.
- C. Replace the self-signed certificate that is installed on the Cisco IMC with a server certificate that is signed from the client corporate certificate.
- D. Se the FQDN of the Cisco IMC webpage login page instead of the IP address for the connection to be secure.
Answer: C
NEW QUESTION 26
An IOM fails during a firmware upgrade and is unresponsive. Which action recovers the module?
- A. Restore UCSM configuration from backup.
- B. Roll back to the previous firmware.
- C. Use AutoInstall to reinstall the firmware.
- D. From the peer IOM, reset the faulty module.
Answer: B
Explanation:
Section: Management and Operations
Explanation/Reference:
NEW QUESTION 27
Refer to the exhibit.
Sw1 and Sw2 are two Cisco Nexus 9000 Series Switches that run Cisco NX-OS. They are VTEPs in the same vPC domain. Which statement describes what happens in this scenario?
- A. Sw1 performs the VxLAN multicast encapsulation and decapsulation for all traffic associated with the VxLAN VNIs.
- B. Sw1 drops all traffic because there is no (S, G) OIF list to encapsulate VXLAN multicast packets and send them out to the underlay network through the uplink interfaces.
- C. Sw2 did not send an IP PIM register to the rendezvous point for the multicast group of the VXLAN VNI.
- D. Sw1 and switch 2 perform the VxLAN multicast encapsulation and decapsulation for all traffic associated with the VxLAN VNIs, depending on the hashing.
Answer: A
NEW QUESTION 28
Refer to the exhibit. A network engineer configures an authentication domain through an LDAP provider on the Cisco UCS Manager for users from different companies to log into their respective organizations created in the UCS Manager. The engineer tests the configuration and notices that any user has login access to any organization in the UCS Manager. Which action should be taken to resolve the issue?
- A. Configure the Attribute field with the company
- B. Configure the Attribute field with sAMAccountName=$company
- C. Configure the Filter field with sAMAccountName=$company
- D. Configure the Filter field with the company
Answer: C
NEW QUESTION 29
A system administrator adds two vNICs to an existing service profile that is used to run a vSphere environment to support disjoint Layer 2 network connectivity. However, after the server is rebooted, the host is not accessible on the network Which action resolves the issue?
- A. Build a new service profile with the desired network configuration
- B. Add the disjoint Layer 2 VLANs to an existing vNIC rather than adding new vNICs
- C. Remove all existing vNICs and add them in the desired order.
- D. Create a vNIC placement policy to avoid adapter renumbering
Answer: D
NEW QUESTION 30 
Refer to an exhibit. An engineer is troubleshooting an upgrade failure on a switch. Which action resolves the issue?
- A. Reload the same system image.
- B. Load a new system image.
- C. Save the system image in NVRAM.
- D. Use the same system image as the kickstart image.
Answer: B
Explanation:
Section: Management and Operations
NEW QUESTION 31 
Refer to the exhibit. After the configuration is performed, guestshell continues to use 2%CPU. Which action resolves the issue?
- A. Reboot the switch
- B. Resync the database
- C. Recreate the guestshell
- D. Reboot the guestshell
Answer: D
Explanation:
Section: Automation
NEW QUESTION 32
Refer to the exhibit.
After a failover occurs, which two actions must be performed on Switch-B to manually preempt the operational primary role back to Switch-A? (Choose two.)
- A. Configure the local vPC role priority to have a higher value than Switch-A.
- B. Configure the local vPC role priority to have a lower value than Switch-A.
- C. Disable and then re-enable the vPC peer link.
- D. Configure the local vPC role priority to have the same value as Switch-A.
- E. Disable and then re-enable the vPC peer-keepalive link.
Answer: A,C
NEW QUESTION 33
Refer to the exhibit.
When an engineer inserts 8-Gb FC SFP port 15 on a Cisco UCS Fabric Interconnect, the port fails. What is a possible cause of the issue?
- A. Port 15 is configured for 4-Gb FC.
- B. Port 15 is missing a license.
- C. The polarity of the fiber cable is reversed.
- D. Port 15 is configured as an Ethernet port.
Answer: A
NEW QUESTION 34
Refer to the exhibit.
During implementation of a Cisco UCS C-Series Server, an engineer receives the status that is shown in the exhibit. Which action resolves the issue.
- A. Set SLOT-1 Sync Mode to "Auto"
- B. Insert an SD card into SLOT-2
- C. Configure the RAID that is associated with the card.
- D. Reconfigure the Drive Type from "Removable" to "Non-Removable"
Answer: D
NEW QUESTION 35
Refer to the exhibit.
The vPC between switcM and switch2 does not work. Which two actions resolve the problem? (Choose two.)
- A. Configure the IP address on the interface.
- B. Configure one of the switches as primary for the vPC.
- C. Correct the configuration of the vPC peer link and the vPC peer keepalive.
- D. Activate VLANs on the vPC.
- E. Match the vPC domain ID between the two devices.
Answer: A,C
NEW QUESTION 36
......
Passing Key To Getting 300-615 Certified Exam Engine PDF: https://www.exam4free.com/300-615-valid-dumps.html
300-615 Exam Dumps Pass with Updated Tests Dumps: https://drive.google.com/open?id=1J3M6pQyU9A2CobG6KCgjjGrqij_1miiJ
